This article describes how to configure data integration between nSPECT and nCORE.
Configuring nCORE/nSPECT Integration
The first step in configuring inspection integration between nCORE and nSPECT is setting up one or more nCORE Evaluation Types to integrate with nSPECT.
When a new Evaluation Type is added to nCORE, a new Inspection Type will be added to nSPECT when the user clicks the checkbox "Enable nSPECT Integration" and saves the record:
Once the "Enable nSPECT Integration" checkbox is clicked, a number of additional settings are displayed, as shown in the image above:
Set Inspection Report to "Final" Status when nSpect Inspection is Completed - the Inspection Report Document will be set to "Final" status in nCORE automatically
nSPECT Inspection Report File Type - Can be set to "docx" or "pdf". Default file type is set in APP_DEPLOY_SETTING where CODE = 'NSPECT_RPT_EXT'
Default Follow-up Evaluation Type - If an Inspection Form in nSPECT is configured to schedule a follow-up evaluation, it will be created with the type specified. If no type is specified, the follow-up will be created as the same type as the current inspection. See section Outbound Tags for more information on configuring Follow-up Evaluations.
Integration tags are configured on nSPECT questions during form design. Integration tags can be used to pass data from nCORE into nSPECT for new inspections and back from nSPECT to nCORE when an inspection is complete.
There are three aspects of data integration between nSPECT and nCORE:
Using Data Integration Tags to prefill nSPECT Forms with data from nCORE and to update nCORE data from completed nSPECT inspections
Using Data Integration Context to populate the nCORE "Inspection Results" tab from a completed nSPECT Inspection
Using Reference / Citation to creating violations in nCORE from questions marked as a violation in nSPECT
These three topics are discussed in the sections below.
When designing an nSPECT form, the Data Integration Tags field is used to to prefill nSPECT Forms with data from nCORE and to update nCORE data from completed nSPECT inspections.
For a complete list of the available data integration tags, see the nCORE / nSPECT Data Integration Tags page.
Using Data Integration Context to populate nCORE Evaluation Results from Completed nSPECT Inspections
The nCORE Evaluation Details page can show a list of questions and answers configured on an nSPECT form for completed inspections. To enable this feature, entering "AREA" into the Data Integration Context field in an nSPECT inspection question.
Questions configured with the text "AREA" in the Data Integration Context will appear along with the answer in the Inspection Results tab in nVIRO.
Using Reference/Citation to Create Violations in nCORE from Completed nSPECT Inspections
Questions marked as violations in nSPECT can be configured to create violation records in nCORE, but must be configured to do so.
In nSPECT, edit the form question that should result in a violation
In the Reference / Citation field, enter a unique value for the violation reference. This value will be used in the next section to map to an nCORE Violation Type/Category
Ensure that the radio button is selected that indicates the user is allowed to mark the inspection as a violation
Click Save at the top of the screen to ensure the changes are saved.
Navigate to the nCORE Admin → Lookups → Violation Types to Categories screen
Either create a new Violation Type to Category Association or edit an existing Violation Type to Category Association that the violation will map to.
In the nSPECT Data Integration Tag field, enter the same value as entered in step 2 above.
Click Save to save the changes.
Note that after saving, beneath the nSPECT Data Integration Tag field, a message will indicate whether the mapping is successful or not by display either one of the following messages:
Technical Aspects if nSPECT to nCORE integration
Steps performed for integration:
On a regular interval, nCORE invokes the Integration - Process Completed nSpect Inspections scheduled task. WSL invokes an nSPECT web service to fetch any completed inspections. If found, the data is staged to EVAL_NSPECT_SUB and EVAL_NSPECT_SUB_DTL staging tables.
Stored procedure SP_IMPORT_NSPECT_DATA is then invoked to move data from the staging tables back to nCORE, including creation of violations.
On a separate schedule, nCORE invokes the Integration - Import nSPECT Submission Files scheduled task. This process copies any new inspection report PDFs from nSPECT into nCORE. Documents are staged in NSPECT_EVAL_FILE_PRCSS. Once the task copies the documents to nCORE, procedure SP_ADD_NSPECT_REQST_FILE performs finalization tasks, such as removing the record from the staging table and setting document statuses to "Final".
Removing an Inspection from nSPECT
In nSPECT, an authorized user can choose "Remove Inspection" from the main Inspections list. When this is done, the inspection is removed from the nSPECT database. A nCORE nightly batch update procedure will set the inspection back to "Planned" that evening.